Emergency Lighting

Installs, Testing & Certification

BS 5266-1 emergency lighting — designed, installed, commissioned and maintained in-house, with monthly function tests, annual full-duration tests and certification after every visit.

Propcare EFS engineer testing life safety systems on site

What it covers

Light on the escape route when the power goes

Emergency lighting keeps escape routes, stairwells, plant rooms and open areas illuminated when the normal supply fails. It has to be correctly designed, regularly tested and properly documented.

We survey the building, put right any gaps in coverage, and take on the testing programme — monthly function tests and the annual three-hour duration test — with remedial works handled by the same team rather than passed to another contractor.

The schedule

Emergency lighting testing frequencies

Intervals set out in BS 5266-1. We schedule them around your building's operation and log every result.

Daily

Central battery systems

A visual check of panel indicators where a central battery system is installed — no testing required.

Monthly

Function ('flick') test

Every luminaire and exit sign is switched to its emergency supply briefly to confirm it illuminates, then checked for correct recharge. Results are recorded in the logbook.

Annually

Full 3-hour duration test

The system runs on battery for its full rated duration — normally three hours — proving it would last a real evacuation. Any fitting that fails is repaired or replaced and the test repeated.

On completion

New installations

Design, install and commissioning certificates issued to BS 5266-1, with photometric coverage confirmed on escape routes and open areas.

Why it matters

Why emergency lighting testing is important

A legal requirement

The Regulatory Reform (Fire Safety) Order 2005 requires escape routes to be adequately illuminated. BS 5266-1 sets out how that's designed, tested and recorded.

Batteries fail quietly

An emergency fitting can look perfectly healthy and still give you seconds instead of hours. Only a duration test proves it.

Evidence on demand

Fire officers, insurers and FM clients ask for the logbook. We keep monthly and annual records complete and current.

Safe evacuation

In a mains failure or a fire, lighting on stairs, corridors and exits is the difference between an orderly evacuation and a dangerous one.

What we deliver

Emergency lighting services

  • Emergency Lighting Design (BS 5266-1)
  • New Installation & System Extensions
  • Monthly Function Testing
  • Annual 3-Hour Duration Testing
  • Illumination & Escape Route Surveys
  • Fitting, Battery & Lamp Replacement
  • Self-Test & Addressable System Takeovers
  • Logbook & Certification Management

Get in touch

Need your emergency lighting tested or installed?

Tell us the site and roughly how many fittings — we'll set the programme up and keep the logbook straight.

Danny Watson

Danny Watson

Co-Owner / Director — Propcare EFS

Direct line — replies within one working day.

FireQual accredited qualification

FireQual Qualified

Our fire safety work is carried out by FireQual-qualified engineers — the awarding organisation for regulated fire safety qualifications in the UK — alongside our NAPIT registration and SafeContractor approval.

UK Fire Door Training Approved Installer
UK Fire Door Training Approved Inspector